Tag: Los Angeles HERS Rater

Los Angeles LA HERS Rater Southern California HERS Rating Duct Testing Refrigerant Charge Title 24.

 

Congratulations to Matt G.

HERS Rater

Matt G. is a newer addition to the DuctTesters team.  Matt joined DuctTesters with a Physical and Biological Science Degree from the College of the Canyons. While attending College, Matt was a member of the “Hands on Earth Club”  and held a strong passion to learn more about sustainability and energy-efficiency. His ambition to grow and educate himself further led him to DuctTesters. Matt joined the team as a HERS Rater Apprentice and shadowed Certified HERS Raters in the field for a few months learning the ins and outs of compliance, efficiency and quality assurance. This hands-on understanding of the building energy code compliance helped Matt with his training to become an official Certified HERS Rater. Matt recently took the CalCERTS training and certification courses and is an official Certified New Residential Construction and Alterations HERS Rater. We are proud of Matt and his dedication to our company.

Congratulations Matt!

 

Facebooktwittergoogle_plusredditpinterestlinkedinmail

What is High Quality Insulation Installation (QII)?

The California Energy Commission (CEC) has set a standard for the way insulation should be installed in a home called High Quality Insulation Installation (QII).  In order to meet QII, insulated framing areas need to resist thermal bridging of the assembly separating conditioned from unconditioned space.  This visual inspection is conducted by a “third party” called a certified HERS Rater.  The HERS Rater (HERS Verifier or HERS Verification) confirms the insulation was installed almost perfectly, allowing the home to perform per the insulation manufacturer’s specifications.  In addition, the HERS rater verifies that compliance meets or exceeds the project’s Title 24 Design or the CF-1R. QII verification almost always requires two visits to conduct full verification.  The first visit is usually held at rough stage (before drywall) and the other is held after.

A few of the items inspected for QII include:

  • the insulation holds the proper R-value and type listed
  • there are no gaps or voids between the framing or insulation
  • there is no insulation compression where restricted from achieving full thickness
  • pipes and wires are in cavities where insulation occurs and are covered with non-compressed insulation in front and back
  • an air barrier is installed at all exposed faces of batt, loose fill, and SPF insulation
  • electrical boxes are carefully cut out in the insulation in order to provide a tight fit with no gaps or holes
  • and more. Review the entire checklist here:  CEC: Quality Insulation Installation (QII) – Insulation Installation Checklist.

If your Title 24 Design or CF-1R requires QII, be sure to contact DuctTesters (a HERS rater) at the beginning of the project. If you do not know what compliance is required for your project, also feel free to contact us.  We can put a proposal together and help you from the beginning through the end of your project.  DuctTesters has a team of certified HERS raters covering the entire state of CA and select areas of NV, NM, CO and AZ. 

**Please note this is DuctTesters interpretation of QII. It is the responsibility of anyone utilizing this information to ensure that it is in compliance with the CEC and CA Title 24 Standards.**

Facebooktwittergoogle_plusredditpinterestlinkedinmail

U.S. Department Of Energy (DOE) shows support for the HVAC Best Practices DuctTesters has been educating on all along

Published in Professional Builder Magazine’s October 2015 Issue:   Sam Rashkin, Chief Architect, Building Technologies Office, U.S. Department of Energy wrote an article titled: “Ensuring Comfort In High-Performance Homes” and it discusses:

  • Duct System Design and Installation
  • Compact System Advantages
    • Lower installation costs.
    • Less leakage.
    • Less equipment.
    • Higher comfort levels.
    • Easier for installers.
    • Less duct damage.
  • Myths of Duct Design
    • Myth 1: Air must be delivered at the window.
    • Myth 2: There’s risk of short-circuiting.
    • Myth 3: The way we’ve always done it is best.

DuctTesters, Inc. has been educating HVAC Best Practices since establishment.  This is a helpful article about efficient innovation, implementing best practices, and debunking myths.  Be sure to read the entire article:

Duct System Design, Duct Testing, HVAC System, High-Performance HomeHVAC Design, Duct Design, HERS, HERS Rater, Title 24, Duct Testing, Duct Tester, Duct Test, Energy Efficient


Full Article as PDF         Link to Article